Signature Service
Water Infiltration Testing
Field water-infiltration testing is the most direct way to verify that an installed assembly performs the way it was designed and specified. PEC performs static and dynamic pressure testing on windows, curtain walls, storefronts, and wall assemblies using calibrated spray racks and digital manometers, with test pressures derived from the project's design requirements.
- ASTM E1105 static and cyclic (dynamic) pressure testing
- AAMA 501.2 nozzle testing for fixed glazing and wall joints
- AAMA 502 (new fenestration) and AAMA 503 (storefront / curtain wall) field testing
- Calibrated spray racks and digital manometers on every test
- Test pressures calculated from project design pressure, with documented reduction factors
- Detailed reports with pass/fail findings, photos, and leak documentation